You are here:  Home > Product Guide > Testers > Precision LC

Precision LC

     Email to a Friend    Bookmark & Share  
 

Excellent Performance

 

The Precision LC is designed to provide excellent performance at a lower cost than the Premier II.

 

It will measure both thin films and bulk ceramics with high fidelity up to 2KHz. It can measure capacitors from 3μ2 up to square centimeters

 

Precision LC Features Include

 

Output Range ±10V, ±100V, ±200V

12-bit Arbitrary Waveform Generator output

100 points in 1ms single-pass

500 points in 10 seconds

Pulse Widths down to 50μs and up to 1s

Fixed 125KV/s output ramp.

 

Polarization Measurement

 
  • 16 bit analog to digital converters – 305μV sensitivity on 100pF Csense
  • 10μs capture rate
  • Polarization, output voltage, and SENSOR inputs captured simultaneously
  • Minimum charge sensitivity -> 30.5fC
  • Minimum PZT capacitor area -> 3.05u2
  • Maximum charge measurement -> 58μC (5.8mC w/HVI)
  • Maximum PZT capacitor area -> 0.58cm2 (58cm2 w/HVI)
  • Maximum hysteresis loop frequency -> 2KHz
  • Minimum hysteresis loop frequency -> 1/10th Hz
  • 1 COMM channels for controlling high voltage amplifiers.
  • 1 26-pin COMM channel
  • 2 external 16-bit, ±10V SENSOR voltage inputs.
  • Requires a desktop or laptop computer with USB1.0 Port or better
  • Can be operated with Windows 2000,Windows XP, or Windows Vista
  • Will execute Hysteresis, Remanent Hysteresis, Small signal CV, IV, fatigue, imprint, retention, and piezoelectric displacement from one hardware
  • configuration.
 

Includes Vision Software

 
Vision Task Library - Hysteresis, Leakage, Charge, Retain, Resist, I/V, Fatigue, C(V), PUND, Imprint, Leakage Current, Remnant Hysteresis, Small signal CV, imprint, retention, and piezoelectric displacement from one hardware configuration. Optional Piezoelectric and Pyroelectric software programs
 

LC Performance Summary

 

The Precision LC tester is capable of executing a single-pass hysteresis loop in 500μs direct acquisition. The LC uses a 1MHz clock. The capture rate for the 16bit ADCs in the system is 100KHz, giving a point density of 100points/millisecond. The LC can execute hysteresis loops lasting up to 10 seconds. The LC will execute a PUND pulse measurement with pulse widths ranging from 50μs up to 1s on capacitors with areas ranging from 3μ2 up to 0.58cm2 or 58cm2 with an HVI attached. The minimum leakage resolution for the LC is ~200fA. The Precision LC has ~1pF of parasitic capacitance between the DRIVE and RETURN.

Detailed Specifications
Precision LC Brochure

Accessories
     High Voltage Testing
     Piezoelectric Testing
     Pyroelectric Testing
     Test Fixtures

Vision Software
Tester Support/Downloads
Request for Quotation
 © 2010 - 2012   Radiant Technologies SiteBuilder by AccuNet